GithubHelp home page GithubHelp logo

Comments (17)

Adminius avatar Adminius commented on August 23, 2024 1

Remove doen't works, it came again, lol
but 0.0 works now

Thanks!

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024 1

Great!

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024 1

Supported Inverters

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

Hi there!

Is there a "supported" or "checked" device list?

Not yet. But list from the original integration should be valid.

But yes this integration is made to work with Solarman Stick Logger so you need that piece of a HW.

As for the support of mentioned device profile 'deye_4mppt.yaml' is probably the one to go...

And when comes to the ESP I'm not really that much familiar to be giving advices.. :/

from ha-solarman.

Adminius avatar Adminius commented on August 23, 2024

Hey @davidrapan I bought M160G4, my problem ist now, that it's serial number ends wirh letter "B" and I can't put letter in to serial number field

image

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

Hi @Adminius, you need serial number from the Solarman Stick Logger and they should only contain numbers.

from ha-solarman.

Adminius avatar Adminius commented on August 23, 2024

yeah...
image
image

this inverter, like other deye micro inverters, has integrated logger.

I tried this integration also with my Deye SUN12K and other micro inverters that worked with "original" Solarman integration and it doen't work at all... (sticks at intiaslisation). May I should go back to "original" Sorarman integration... sadly :/

EDIT: Am I on the wrong way? Inverter Serial or Solarman Serial?

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

Solarman serial, its little bit lower on the screenshot you sent here.

On this row:
solarman_sn

Edit: If you used latest Stephans integration it has to work with mine too they use the same library for solarman protocol. I'm personally running SG04LP3.

Edit2: It is possible that for string inverters you gonna need beta pre-release of this integration. which you can enable using Redownload under 3 dots button menu in top right corner on the HACS page. Then just select the latest version (24.07.29) and click DOWNLOAD.

from ha-solarman.

Adminius avatar Adminius commented on August 23, 2024

Now I used the Solarman Serial
image

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

It is possible that for string inverters you gonna need beta pre-release of this integration. which you can enable using Redownload under 3 dots button menu in top right corner on the HACS page. Then just select the latest version (24.07.29) and click DOWNLOAD.

You are using 24.07.24

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

Also always enable debug on the same page you just showed me the screenshot from and send logs which it produces without it I really can't help you much. Logs are crucial.

from ha-solarman.

Adminius avatar Adminius commented on August 23, 2024

sm_debug_M160G4.txt
Here is debug from one M160G4 only

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

So it is working great but it gets some incorrect data for Total Production:

ValueError: Invalidate complete dataset (Total Production ~ 0.0)

Which profile are you loading?

from ha-solarman.

Adminius avatar Adminius commented on August 23, 2024

Oha, it is comletely new inverter, yesterday connected to PV panels (WiFi Setup and so on), but not to the grid yet, that's why 0 kWh production

Profile: 4mppt

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

Remove that invalidation from the profile you are loading.

From:

- name: "Total Production"

Remove that:

    invalidate_all:

Under:

  validation:

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

I'm gonna remove it from the repository too as it really does not make any sense for it being there. Cause as you can see it causes troubles for any new inverter, lol.

I will probably change it to:

validation:
  min: 0.0
  invalidate_all:

So 0.0 is an okay value for the validation.

from ha-solarman.

davidrapan avatar davidrapan commented on August 23, 2024

2a10012

from ha-solarman.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.