This project applies supervised machine learning to a public, real-world multi-sensor IoT dataset to predict fire alarms — with the operational goal of reducing false alarms while keeping high recall on real fires. It is the first project in the capstone series that produces a defensible model evaluation methodology (rules-first, leakage-aware, regime metrics) carried into the later agentic and synthesis projects.
- Dataset: Smoke Detection Dataset (Kaggle
deepcontractor/smoke-detection-dataset) — 62,630 rows × 13 sensor features + binary targetFire Alarm. - Models: threshold rule, Random Forest, Gradient Boosting, Logistic Regression, Isolation Forest.
- Headline result: a random train/test split reports F1 ≈ 0.9998 for the tree models — but a built-in leakage audit shows that number is an artifact. Under Leave-One-Session-Out (LOSO) cross-validation, Random Forest scores 0.000 sensitivity on held-out fire sessions (it misses 100% of alarms it hasn't seen), while the simple threshold rule transfers best (sensitivity 0.57, specificity 0.999 on the held-out fire session).
- Takeaway: the models learn session-specific sensor signatures, not transferable fire signatures. The binding constraint is data diversity, not the algorithm.
project_03_ML/
├── README.md # this file
├── requirements.txt # pinned environment (pip freeze)
├── .gitignore
├── data/
│ ├── raw/
│ └── smoke_detection_iot.csv # the dataset (~5.6 MB, shipped with the repo)
├── notebooks/
│ └── modeling.ipynb # Tasks 1–6 + "A second look" leakage audit
└── reports/
├── Machine_Learning_Analysis_Report.md # Task 7 report source (APA citations)
├── Machine_Learning_Analysis_Report.pdf # Task 7 deliverable (PDF)
└── md2pdf.py # markdown → PDF converter for the report
| Property | Value |
|---|---|
| Source | Kaggle — deepcontractor/smoke-detection-dataset |
| Rows | 62,630 |
| Columns | 13 sensor features + UTC + CNT + target Fire Alarm |
| Missing values | None |
| Feature types | All numeric (float64 / int64) |
| Target balance | 71.5% alarm / 28.5% no-alarm |
| File | data/raw/smoke_detection_iot.csv (~5.6 MB, shipped with the repo) |
Sensor features: Temperature[C], Humidity[%], TVOC[ppb], eCO2[ppm], Raw H2, Raw Ethanol, Pressure[hPa], PM1.0, PM2.5, NC0.5, NC1.0, NC2.5.
A decisive property (discovered in the notebook's audit): the dataset is 5 continuous recording sessions from one device, not 62,630 independent samples — 62,625 of 62,629 row-to-row gaps are exactly 1 second.
Rules-first → ML upgrade, with a leakage audit:
- Baseline threshold rule —
Fire Alarm = 1 if Temperature[C] > 15 AND TVOC[ppb] > 200(thresholds tuned by grid search on F1). Interpretable, cannot memorize. - Random Forest — 200 trees,
max_depth=15,min_samples_leaf=5. - Gradient Boosting — scikit-learn
GradientBoostingClassifier. - Logistic Regression — linear baseline (scale-sensitive, behind a
StandardScalerpipeline). - Isolation Forest — unsupervised anomaly detector (trained on the full scaled training set, never given the label).
Evaluation protocol:
- Initial (naive) procedure: stratified 80/20 random split → accuracy/precision/recall/F1 table. (Produces the misleading 0.9998.)
- "A second look" (leak-proof): Leave-One-Session-Out CV over the 4 independent recording sessions (duplicate fire sessions 1+2 collapsed into one unit), reporting per-session sensitivity and specificity — the regime metrics that map onto the false-alarm-reduction goal.
| Model | Accuracy | Precision | Recall | F1 |
|---|---|---|---|---|
| Random Forest | 0.9997 | 0.9997 | 0.9999 | 0.9998 |
| Gradient Boosting | 0.9998 | 0.9998 | 0.9999 | 0.9998 |
| Logistic Regression | 0.9268 | 0.9268 | 0.9745 | 0.9501 |
| Baseline rule | 0.6390 | 0.8962 | 0.5596 | 0.6890 |
| Isolation Forest | 0.2684 | 0.3450 | 0.0265 | 0.0492 |
| Model | Held-out fire session: sensitivity | Held-out quiet session: specificity |
|---|---|---|
| Baseline rule | 0.566 | 0.667 / 0.857 |
| Random Forest | 0.000 | 0.903 |
| Gradient Boosting | 0.264 | 0.000 (fires on everything) |
| Logistic Regression | 0.000 | 0.971 |
| Isolation Forest | 0.000 | bimodal (0 or 1.0) |
Honest conclusion: with leakage removed, the simple threshold rule transfers best across sessions. The ML models overfit to the recording they were trained on — exactly what produced the naive section's 0.9998. Full per-session table and the audit code are in the notebook.
- Python 3.11+ (developed on the project-local
p3_venv) - Packages: see
requirements.txt(pinned). Core deps:scikit-learn,pandas,numpy,matplotlib,scipy,jupyter.
# from the project root:
# Windows (PowerShell)
. .\p3_venv\Scripts\Activate.ps1
# Linux / macOS
source p3_venv/bin/activate
# install pinned deps if starting fresh
python -m pip install -r requirements.txtThe dataset is already in data/raw/ — no download step.
# interactive:
jupyter lab notebooks/modeling.ipynb
Expected runtime: ~2–3 minutes. All cells should execute without error.
Sanity check after running: the "A second look" LOSO table should show Random Forest sensitivity = 0.000 on the held-out fire session and Baseline rule sensitivity ≈ 0.566 on the same session. If those numbers differ, the session-id assignment in the audit cell has drifted and should be re-checked.
| Deliverable | Status |
|---|---|
notebooks/modeling.ipynb |
✅ complete (Tasks 1–6 + leakage audit) |
data/raw/smoke_detection_iot.csv |
✅ shipped |
requirements.txt |
✅ generated from p3_venv via pip freeze |
reports/Machine_Learning_Analysis_Report.pdf |
✅ generated (Task 7) |
The leakage audit is itself the most defensible part of this project: it finds and corrects an evaluation trap that a single-number metric would have hidden. The transferable artifact for the later agentic (P6) and synthesis (P7) projects is methodology + the threshold rule, not a frozen ML model:
- Threshold rule — transferable; expose as the cold-start fire detector.
- Per-site ML calibration — train on a site's own history once it exists; the in-distribution ~0.9998 is real for a given site.
- Methodology — rules-first, audit-the-split-for-the-independence-unit, report regime metrics, honest failure reporting. P7's fusion risk-scorer inherits this discipline on its own synthetic incident data.
Full handoff details are in the root capstone CLAUDE.md under
"P3 → P6/P7 integration note".
- Binding constraint is data diversity, not the algorithm. Four independent recording sessions from one device cannot yield a model that generalizes across sites.
- The 0.9998 F1 was a leakage artifact from a random split on autocorrelated rows — corrected by LOSO.
- Inherited label bias: the
Fire Alarmlabel was assigned by the prototype hardware, not independent ground truth; any model inherits that definition of "fire signature." - Single-device, single-environment sampling bias — no variation in sensor placement, building type, or occupant behavior.
- Per-site re-tuning required — the rule's thresholds reflect this prototype and would need calibration in a different environment.
Detailed discussion in reports/Machine_Learning_Analysis_Report.pdf
(Sections 6.1–6.3).
If you reference this work, please cite the dataset and the rubric framework:
- deepcontractor. (2022). Smoke detection dataset [Data set]. Kaggle. https://www.kaggle.com/datasets/deepcontractor/smoke-detection-dataset
Full academic references (Breiman 2001, Friedman 2001, Liu et al. 2008, Roberts et al. 2017, Mehrabi et al. 2021, etc.) are in the report's References section.
Educational project for the Udacity AI Mastery Capstone. The dataset is publicly available under its Kaggle terms; this repo ships the CSV for reproducibility only. No biometric or PII data is used — the system operates on sensor metadata only.