HeishaMon Rules

Some introduction

Here you find a collection of different rules to use with the HeishaMon.

Special thanks to @CurlyMoo and @blb4github. Most of the rules are inspired by their work.

Warning

Usage of the rules is at your own risk.

Instructions

You can pick and mix the functions you like. To start you always need the System#Boot section, this is where the basics are configured.

on System#Boot

This is the first section of the ruleset. Here you can confiugre some settings and are global variables defined. Default all functions are disabled (the #allow* variables), you can enable them by setting 0 to 1.

The second part of the global variables are mostly helpers. Where possible the are defaulted to -1 so you can monitor the results of the functions easily.

At the end the first timer, 1, is set to run after 10 seconds. This timer is also set in this block. This is our global timer that recurs every 30 seconds to hendle all the main functions.

System#Boot
on System#Boot then
    #allowSyncOT = 0;
    #allowCalcHeatCurve = 0;
    #allowSetQuietMode = 0;
    #allowshiftOnOpenTherm = 0;
    #allowSetMaxPumpDuty = 0;

    #chEnable = -1;
    #maxTa = -1;
    #quietModeHelper = 1;
    #quietModePrevious = -1;
    #chEnableCntr = -1;
    #chDisableCntr = -1;
    #chShiftHelper = 2;
    #pumpDutyHelper = -1;
    #maxPumpDuty = 85;
    setTimer(1,10);
end

on timer=1 then
    calcHeatCurve();
    syncOpenTherm();
    setQuietMode();
    shiftOnOpenTherm();
    setMaxPumpDuty();
    setTimer(1,30);
end

syncOpenTherm

This function synchronizes the heatpump values with your OpenTherm thermostat.

syncOpenTherm
on syncOpenTherm then
    if #allowSyncOT == 1 then
        ?outletTemp = @Main_Outlet_Temp;
        ?inletTemp = @Main_Inlet_Temp;
        ?outsideTemp = @Outside_Temp;
        ?dhwTemp = @DHW_Temp;
        ?dhwSetpoint = @DHW_Target_Temp;
        if ?chEnable == 1 then
            #chEnable = 1;
        else
            #chEnable = 0;
        end
    end
    #dhwEnable = ?dhwEnable;
    if #maxTa != -1 then
        ?maxTSet = #maxTa;
    end
    if @Compressor_Freq == 0 then
        ?flameState = 0;
        ?chState = 0;
        ?dhwState = 0;
    else
        ?flameState = 1;
        if @ThreeWay_Valve_State == 0 then
            ?chState = 1;
            ?dhwState = 0;
        else
            ?chState = 0;
            ?dhwState = 1;
        end
    end
end

calcHeatCurve

This function calculates the target temperature based on the configured Heat Curve

When using syncOpenTherm the #maxTa value will be synced to the thermostat as ?maxTSet.

calcHeatCurve
on calcHeatCurve then
    if #allowCalcHeatCurve == 1 then
        if isset(@Z1_Heat_Curve_Target_Low_Temp) && isset(@Z1_Heat_Curve_Outside_High_Temp) && isset(@Z1_Heat_Curve_Target_High_Temp) && isset(@Z1_Heat_Curve_Outside_Low_Temp) && isset(@Outside_Temp) then
            $Ta1 = @Z1_Heat_Curve_Target_Low_Temp;
            $Tb1 = @Z1_Heat_Curve_Outside_High_Temp;
            $Ta2 = @Z1_Heat_Curve_Target_High_Temp;
            $Tb2 = @Z1_Heat_Curve_Outside_Low_Temp;
            $Tb3 = @Outside_Temp;
            if $Tb3 >= $Tb1 then
                #maxTa = $Ta1;
            else
                if $Tb3 <= $Tb2 then
                    #maxTa = $Ta2;
                else
                    #maxTa = 1 + floor(0.9 + $Ta1 + (($Tb1 - $Tb3) * ($Ta2 - $Ta1) / ($Tb1 - $Tb2)));
                end
            end
        end
    end
end

setQuietMode

This function sets the quiet mode based on a combination of the current time and the value of @Outside_Temp. It will help the heatpump running more stable and in low frequencies.

Important

Using this function will enable quiet mode which might impact your power usage and the performance of your heatpump.

setQuietMode
on timer=2 then
    #quietModeHelper = 1;
    #quietMode = 0;
end

on setQuietMode then
    if #allowSetQuietMode == 1 then
        if isset(@Outside_Temp) && isset(@Heatpump_State) then
            if #quietModeHelper == 1 then
                if @Outside_Temp < 13 then
                    #quietMode = 1;
                else
                    #quietMode = 2;
                end
                if @Outside_Temp < 8 then
                    #quietMode = 0;
                end
                if @Outside_Temp < 2 then
                    if %hour > 22 || %hour < 7 then
                        #quietMode = 1;
                    else
                        #quietMode = 0;
                    end
                end
                if #quietModePrevious != #quietMode && @Heatpump_State == 1 then
                    setTimer(2, 900);
                    #quietModeHelper = 0;
                    #quietModePrevious = #quietMode;
                    @SetQuietMode = #quietMode;
                end
            end
        end
    end
end

setMaxPumpDuty

This function adjust the pump duty based on the state of the heatpump and the outside temperature.

setMaxPumpDuty
on setMaxPumpDuty then
    if #allowSetMaxPumpDuty == 1 then
        #pumpDutyHelper = #pumpDutyHelper + 1;
        if #pumpDutyHelper == 6 then
            #pumpDutyHelper = 0;
            if @ThreeWay_Valve_State == 1 && @Max_Pump_Duty != 220 then
                @SetMaxPumpDuty = 220;
            end
            if @ThreeWay_Valve_State == 0 && @Heatpump_State == 1 then
                if @Outside_Temp < 10 then
                    $MPF = 11;
                else
                    $MPF = 10;
                end
                if @Outside_Temp < 5 then
                    $MPF = 12;
                end
                if @Outside_Temp < 2 then
                    $MPF = 13;
                end
                if @Compressor_Freq == 0 then
                    $MPF = 8;
                end
                if @Pump_Flow < $MPF then
                    #maxPumpDuty = #maxPumpDuty + 5;
                else
                    if @Pump_Flow > $MPF + 1 then
                        #maxPumpDuty = #maxPumpDuty - 1;
                    end
                end
                if #maxPumpDuty > 140 then
                    #maxPumpDuty = 140;
                end
                if @Max_Pump_Duty != #maxPumpDuty then
                    @SetMaxPumpDuty = #maxPumpDuty;
                end
            end
        end
    end
end

shiftOnOpenTherm

Warning

This function is still in experimental phase.

This function shifts the request temperature up based on the chEnable status of the thermostat. If the thermostat is requesting heat for longer then 30 minutes, the @SetZ1HeatRequestTemperature is shifted to the value set in #chShiftHelper (see the System#Boot section) to speed up your warm up process. If the thermostat doesn't request any heat for longer then 30 minutes, the @SetZ1HeatRequestTemperature is set back to 0.

shiftOnOpenTherm
on shiftOnOpenTherm then
    if #allowshiftOnOpenTherm == 1 then
        if ?chEnable == 0 && ?chSetpoint == 10 then
            #chDisableCntr = #chDisableCntr + 1;
        end
        if ?chEnable == 1 && ?chSetpoint != 10 then
            #chEnableCntr = #chEnableCntr + 1;
        end
        if #chEnableCntr == 60 then
            if #chShiftHelper != 2 then
                #chShiftHelper = 2;
                @SetZ1HeatRequestTemperature = 2;
            end
            #chEnableCntr = 0;
        end
        if #chDisableCntr == 60 then
            if #chShiftHelper != 0 then
                #chShiftHelper = 0;
                @SetZ1HeatRequestTemperature = 0;
            end
            #chDisableCntr = 0;
        end
    end
end

heishamonrules's People

Contributors

fbloemhof avatar

Watchers

 avatar  avatar

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    ๐Ÿ–– Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. ๐Ÿ“Š๐Ÿ“ˆ๐ŸŽ‰

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google โค๏ธ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.