martinemde/ha-magic-climate

Home Assistant integration that wraps any climate.* entity to add UI-configured presets and an auto-detected dual-setpoint. Targeting Mitsubishi Heat Pumps first

★ 0Forks 0PythonGitHub ↗Compare
esphomehome-assistanthome-assistant-custom-componenthome-assistant-integration

README

Magic Climate

A generic Home Assistant custom integration that wraps any climate.* entity to add:

  • UI-configured presets — define Comfort, Away, Eco, Boost and Sleep bands in HA's options flow. No YAML. No device reflashing.
  • Dual-setpoint UI fix — auto-detected. Climate entities that support HEAT_COOL with target_temperature_range get one slider in HEAT/COOL/AUTO and two in HEAT_COOL. The native HA thermostat card otherwise misbehaves for these entities.
  • Fahrenheit normalization — auto-detected. Source entities that report °F on a °F HA instance no longer trigger HA's double-conversion bug.
  • A Home preset that follows the clock — Home holds Comfort by default, swaps to Eco during peak hours, to Boost while preloading ahead of them, and to Sleep overnight, still reporting home throughout. Pick any of those yourself to pin it.

Installation

HACS (recommended)

  1. HACS → Integrations → ⋮ → Custom repositories.
  2. Add https://github.com/martinemde/ha-magic-climate as an Integration.
  3. Install Magic Climate.
  4. Restart Home Assistant.

Manual

Copy custom_components/magic_climate/ to your HA config directory and restart.

Setup

  1. Settings → Devices & Services → + Add Integration → Magic Climate.
  2. Pick the source climate.* entity to wrap. This is permanent for the entry.
  3. (Optional) give the wrapper a display name.

Defining presets

Settings → Devices & Services → Magic Climate → Configure. Everything is on one page, because none of these bands means anything on its own: Eco is Comfort minus what you will pay for at peak, Boost is what you do to Comfort just before that, and Sleep is Comfort with nobody watching.

Section What it is
Home (Comfort) Your standard band. Home holds it unless something below moves it.
Eco energy saver The band for when energy costs more, plus the peak window and the switch that has Home swap into it.
Boost A band that drives the room past Comfort while power is cheap, plus how many minutes before peak to start.
Sleep The overnight band and its window.
Away The band for an empty house. No schedule — wire an away trigger in HA to select it.

Each band is a low, a high, and an optional fan mode taken from what the wrapped entity reports in fan_modes. Presets carry no HVAC mode: heating or cooling is a seasonal decision made once for the unit, not something a comfort band should flip on the way past.

Eco, Boost and Sleep each have a checkbox that creates the preset. Creating one only adds it to the picker — it starts applying on its own when you also give it a window (and, for Eco, switch on "Home switches between Comfort and Eco"). Leave the times blank and the band exists purely to be selected, by you or by an automation.

Changes persist in HA's config storage and are picked up immediately. No restart.

How Home resolves

Home holds no band of its own. It resolves by the wall clock, in this order:

Window open Home applies
Sleep the Sleep band
Peak the Eco band
Preload (the run-up to peak) the Boost band
nothing the Comfort band

Sleep outranks peak on purpose: a night band exists because someone is asleep in the room, and the saving from holding Eco through it is not worth waking up for. Boost sits under peak only for completeness — the preload window ends exactly where peak begins, so the two never actually overlap.

preset_mode reads home the whole time. That is the point: the label never changes, so nothing downstream sees an event to react to, and drift is measured against the band really pushed rather than against Comfort. The band in force is published separately as effective_preset.

Selecting anything else pins it. Comfort during peak holds Comfort. Eco at noon holds Eco. That is also what makes a preset with blank times useful — it is reachable only that way.

While nothing is scheduled, Home is the Comfort band, and Comfort is left out of the picker rather than sitting there as a second name for the same setpoints.

How presets apply

A preset always declares a band (low + high). When one is applied, the wrapper pushes setpoints to the source based on the source's current HVAC mode:

Source mode Pushed
heat_cool target_temp_low = low, target_temp_high = high
auto temperature = midpoint (the unit applies its own deadband)
heat temperature = low
cool / dry temperature = high
fan_only / off nothing

A declared fan is pushed after the temps.

Applying is one-shot — push, then walk away. There is no control loop and no re-assertion on drift: any manual change clears the preset label, which is also what stops the schedule from ever fighting a wall thermostat that has taken the setpoint. The only write the wrapper makes unasked is moving Home across a window boundary, and that fires only while Home is still the held preset.

The held preset survives a Home Assistant restart. The label alone would be a claim about hardware nobody was watching, so the push it implies is reconstructed and handed to the normal drift check. If something moved the setpoint while HA was down, the preset clears on the first source update, exactly as it would have without the restart. The one exception is a window boundary crossed while HA was down, which has no boundary left to fire and is re-applied at startup.

Published state

Attribute Example
effective_preset "eco" while preset_mode reads "home"
peak_active true
peak_start / peak_end "16:00:00" / "21:00:00"
next_peak_start / next_peak_end "2026-08-29T16:00:00-07:00"

Peak boundaries are published as absolute timestamps so an automation can act ahead of the window. They change at most a few times a day, so they do not churn the recorder.

How the dual-setpoint UI fix works

If the source's supported_features includes both TARGET_TEMPERATURE_RANGE and HEAT_COOL in hvac_modes, the wrapper masks TARGET_TEMPERATURE_RANGE out in modes other than HEAT_COOL (and OFF for entities that idle from HEAT_COOL). The thermostat card renders the right number of sliders for each mode.

In FAN_ONLY the wrapper masks out both temperature flags and reports no setpoint at all. The source still holds a band, because it stays two-point internally, but neither side drives anything in that mode — so any number shown there is fiction, and a fiction the user can nudge, which writes a real bound. Dropping the flags makes Home Assistant refuse the write before it reaches the entity.

Otherwise the wrapper does pure pass-through.

Minimum setpoint span

The wrapped unit is two-point internally even while the wrapper presents one slider, so the bound you are not setting still matters: left parked next to the one you are setting, it makes the unit clamp, and the setpoint echoes back a degree off what you asked for.

So a manual write slides the other bound out of the way, keeping at least MIN_SETPOINT_SPAN_C (4 °C, matching the amplitude the CN105 firmware enforces for itself in AUTO). Cooling pulls the heating bound down; heating pushes the cooling bound up. Two limits on that:

  • It slides only toward the minimum. A band already wider is left alone — that is the user's choice, not something to normalise.
  • It stops at the source's own min_temp/max_temp. A bound pushed outside them makes Home Assistant reject the whole call, which would lose the setpoint that was actually asked for, so a narrower deadband is the better trade.

Presets are exempt: a preset names both edges deliberately, so its span is whatever it was configured to be.