Configure HP Array Controllers using Docker
- Usage examples:
# docker run --rm --privileged rmarchei/hpacucli version
ACU CLI Version: 9.40.12.0
SoulAPI Version: 6.2.25.0
# docker run --rm --privileged rmarchei/hpacucli ctrl all show config
Smart Array P420i in Slot 0 (Embedded) (sn: 0011223344AABC0)
array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (838.3 GB, RAID 1+0, OK)
physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300.0 GB, OK)
physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300.0 GB, OK)
physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300.0 GB, OK)
physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300.0 GB, OK)
physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300.0 GB, OK)
physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 300.0 GB, OK)
Enclosure SEP (Vendor ID HP, Model Gen8 ServBP 12+2) 378 (WWID: 1234567892DB3B59, Port: 1I, Box: 1)
Expander 380 (WWID: 1234567892DB3B40, Port: 1I, Box: 1)
SEP (Vendor ID PMCSIERA, Model SRCv8x6G) 379 (WWID: 1234567895CA79CF)
# docker run --rm --privileged -it rmarchei/hpacucli
HP Array Configuration Utility CLI 9.40.12.0
Detecting Controllers...Done.
Type "help" for a list of supported commands.
Type "exit" to close the console.
=>